Sector statutory inspections

Statutory Inspections for Schools, Colleges & Universities

LOLER, PUWER, PSSR and COSHH LEV compliance from one independent inspection body.

An education estate hides a full statutory workload: passenger lifts and hoists under LOLER, fume cupboards and DT extraction under COSHH, and the prep room autoclave under PSSR, because steam is a relevant fluid at any pressure.

SEIS schedules the whole programme into holidays and quiet weeks, with enhanced DBS checked engineer surveyors and reports the estates file can show any auditor.

  • Independent & impartial
  • Competent engineer surveyors
  • Reports issued promptly
14 months
Maximum interval for fume cupboard and LEV testing
Any pressure
The prep room autoclave sits under PSSR
6-monthly
Cycle for passenger lifts and people-lifting equipment
DBS checked
Every engineer surveyor on site

Education cover

  • Schools, academy trusts, colleges and universities
  • Enhanced DBS checked engineer surveyors
  • Examinations in holidays and around timetables
  • One programme across a multi-site trust
What needs inspecting

What needs inspecting across an education estate

Three regimes carry the estate. LOLER covers everything that lifts, on the fixed 6 and 12 month cycles. COSHH Regulation 9 puts every fume cupboard and every DT extraction system on a thorough examination and test at least every 14 months, benchmarked to HSG258 and, for science, CLEAPSS G9. PSSR covers the boiler house and the autoclaves.

EquipmentRegimeStatutory positionWhat you receive
Passenger liftsLOLERThorough examination at least every 6 monthsReport of Thorough Examination
Access platform lifts and stairliftsLOLEREvery 6 months where they carry peopleReport of Thorough Examination
Kitchen dumbwaiters and goods liftsLOLEREvery 12 months where they carry loads onlyReport of Thorough Examination
Theatre and hall winches and riggingLOLEREvery 12 months, with accessories every 6, or per the examination schemeReport of Thorough Examination
Science fume cupboardsCOSHHThorough examination and test at least every 14 months under COSHH Regulation 9LEV test report to HSG258
DT workshop dust and fume extractionCOSHHAt least every 14 months, sooner where risk assessment demandsLEV test report
Prep room autoclaves and sterilisersPSSRSteam is a relevant fluid at any pressure, so a certified Written Scheme appliesWritten Scheme certification and examination report
Boiler house plantPSSRExamination to the Written Scheme, report within 28 daysWritten Scheme certification and examination report
DT machinery (lathes, saws, sanders)PUWERInspection at risk-based intervals set by a competent personWritten record of inspection

There is no PUWER certificate: DT machinery inspections produce a written record kept at least until the next one. Fume cupboard test reports are kept for five years.

Sector compliance

The estate the timetable never sees

Education compliance fails quietly: the fume cupboard that drifted past 14 months during a busy year, or the autoclave nobody realised was a pressure system. Both are exactly what an HSE visit after an incident asks about first.

Science and DT are statutory territory

Every fume cupboard is local exhaust ventilation in law, tested to HSG258 with CLEAPSS G9 as the education benchmark, at least every 14 months with reports kept five years. The DT workshop's dust and fume extraction carries the same duty, and wood dust makes it one the HSE actively enforces.

The autoclave is the one that surprises estates teams: steam has no minimum threshold under PSSR, so even a benchtop steriliser needs a certified Written Scheme of Examination before use and examination to that scheme.

How SEIS works around a school year

Examinations are planned into holidays, INSET days and exam-season quiet weeks, so a lift is never out of service at drop-off and a lab is never closed mid-term. Every engineer surveyor attending is enhanced DBS checked as standard.

For academy trusts and university estates the programme runs across every site in one calendar, with reports in the client portal by site and by room, which is what turns an audit request from a week of chasing into an afternoon.

Sector deep dive
Part 1 of 8

The school estate: laboratories, workshops and lifts on a term time clock

A school or college runs a statutory estate that would surprise most of its leadership team. The science department's fume cupboards are LEV under COSHH, on the 14 month thorough examination and test cycle. The DT workshop's dust and fume extraction is LEV on the same clock. The prep room autoclave is a pressure system the moment it raises steam, needing a Written Scheme of Examination under PSSR. The passenger and platform lifts are people lifting equipment on the LOLER 6 month tier. And the workshop machinery, kilns, and site equipment sit under PUWER with written inspection records.

The school duty mapCOSHHfume cupboards, DT LEV: 14mPSSRautoclave: steam, to schemeLOLERpassenger, platform lifts: 6mPUWERDT machines: written recordsTHE CLOCKS14mWSE6mtermly
The school mapped: fume cupboards and DT extraction on the 14 month clock, the autoclave to its Written Scheme, lifts on 6 months, machinery under PUWER.

Two things make education distinctive. The exposed population includes children, which raises the standard of care every regime is judged against. And the calendar is gift wrapped: no other sector gets thirteen empty weeks a year in which every examination can happen without disturbing a soul, which makes an out of date fume cupboard in an occupied school particularly hard to defend.

The duty holder is the employer, which depending on structure means the trust, the governing body or the authority, and the practical owner is usually the site manager or business manager. This guide gives that person the map and the term time calendar.

Key point

Fume cupboards, DT extraction, the autoclave, the lifts and the machinery each carry a statutory clock, and the school year hands you thirteen empty weeks to run them all in: the estate is only hard if it is unmapped.

Part 2 of 8

Fume cupboards and DT extraction: the 14 month clock in term time

Every fume cupboard in the science department is local exhaust ventilation: the control that keeps experiment fumes out of pupils' and technicians' breathing zones, and under COSHH Regulation 9 it must be thoroughly examined and tested at least every 14 months by a competent person, against the performance it was installed to deliver, face velocity at the working sash height above all. The DT department doubles the estate: wood dust extraction on the saws and sanders, weld bay fume extraction where metalwork runs, and soldering extraction in electronics, all LEV, all on the same 14 month cycle, all judged hood by hood against benchmarks.

Schools fail these tests in characteristic ways. Fume cupboards used as storage until airflow patterns bear no resemblance to commissioning; sashes propped past their working height; DT extraction that survived a workshop reorganisation nobody recalculated; and the quiet decommissioning, a cupboard that failed once and became a display case without anyone formally taking it out of service, which leaves the department one short the day the curriculum needs it.

The between test discipline belongs to the technicians: weekly checks that airflow indicators read where they should, sashes travel and hold, and dust visibly leaves the DT machines it is meant to leave. A cupboard or hood that fails the eye test is out of use that lesson, not at the next annual service.

Key point

Every fume cupboard and every DT hood is LEV on the 14 month clock, judged against its commissioning: keep sashes at working height, keep cupboards empty of storage, and treat visible escape as a same lesson stoppage.

Part 3 of 8

The autoclave, the lifts and the machinery: the estate beyond the labs

The prep room autoclave earns its own attention because PSSR applies to steam at any pressure: even a bench top steriliser is a pressure system when it raises steam, needing a Written Scheme of Examination certified by a competent person before use and examinations to that scheme with reports in 28 days. Many schools discover this duty by letter from an insurer; the better discovery is one planned visit. Kilns, air compressors in DT, and any boiler house plant join the same conversation where they cross the thresholds.

The lifts carry LOLER's people tier: passenger lifts and platform lifts serving accessibility are examined every 6 months, with the school, trust or authority as duty holder, independent of whoever holds the maintenance contract, and a lift idle over a long closure is re examined before it carries anyone again. Stage and hall equipment deserves a line of its own: motorised or winched lighting bars and any flying equipment over a stage are lifting equipment, examined accordingly, because the load hangs over children at assembly.

The machinery estate runs on PUWER: DT machines with guarding, braking and isolation confirmed on a written record, site equipment from mowers to the caretaker's bench grinder maintained in an efficient state, and the records dated and signed on intervals the school sets. None of it is beyond a competent site team; all of it must be written down.

Key point

Steam at any pressure puts even the bench top autoclave on a certified scheme, the lifts and anything hung over a stage run on LOLER, and the DT machines need written guarding and braking records: the estate beyond the labs is small but entirely statutory.

Worked example

Worked example: the September the fume cupboards came back out of date

A secondary school runs eight fume cupboards, tested every summer for years by an arrangement nobody quite owns: the science technician books it when the reminder comes. The technician retires in the spring; the reminder goes to a dormant inbox; September opens with the whole estate's tests lapsed since the 14 months expired in August, discovered when a new technician looks for the certificates during a chemistry risk assessment review.

last test14 months: lapsed in AugustThe estate that lived in one inboxscience: 8 cupboards
Eight fume cupboards, one retired technician and a reminder in a dormant inbox: the estate lapsed in August and term started anyway.

The school does the right thing at the wrong cost: practical work needing the cupboards pauses, the testing is booked at short notice in term time, and two cupboards fail on face velocity, one from a failed fan belt, one found half full of stored glassware that had wrecked its airflow. Three weeks of curriculum are reshuffled around a duty that thirteen empty weeks in the year existed to absorb. The head's report to governors asks the right question: how did a statutory date live in one person's inbox?

The rebuild is administrative and permanent: every statutory date, LEV, autoclave scheme, lifts, machinery records, moved onto the school's central compliance calendar alongside fire and legionella, owned by the business manager, booked into holiday windows a term ahead, with the 14 month drift diaried from each test's own date. The next lapse would now need the whole office to retire at once.

Key point

Statutory dates die in personal inboxes: put the 14 month LEV clock, the scheme, the lifts and the records on the school's central compliance calendar, booked a term ahead into the holidays the sector is given for exactly this.

Part 5 of 8

Signs a school's statutory estate is running on one person's memory

Fume cupboard or DT extraction test dates held in one member of staff's inbox
The 14 month cycle managed as the annual summer test until it quietly slips past
Fume cupboards used as storage, or sashes habitually propped above working height
An autoclave raising steam in the prep room with no certified Written Scheme
A cupboard or hood that failed once and became a display case with no formal removal from service
Lifts examined by the same contractor that maintains them, or restarted after closures unexamined
Lighting bars and stage flying equipment absent from any lifting register
DT machinery with guarding and braking checked by habit and recorded nowhere
No single compliance calendar that a new business manager could pick up cold
Key point

Every flag is single point of failure administration: the estate survives staff turnover only when its dates live on the institution's calendar, not in anybody's memory.

Part 6 of 8

The school calendar: thirteen empty weeks, used on purpose

Education's statutory calendar should be the easiest in this series, because the scheduling windows are printed a year in advance. The 14 month LEV cycle lands wherever its drift puts it, so book each test into the nearest holiday ahead of the due date, never the one after, and accept that the anchor walks through the year by design. The autoclave and any pressure plant examine to their scheme intervals, placed in the same windows. The lifts' 6 month cycle pairs naturally with the summer and Christmas breaks. And the PUWER records on DT machinery run termly, with the caretaking team's checks continuous.

The school yearJFMAMJJASONDLEV testsdriftsLiftsx2 a yrAutoclaveto WSEDT recordstermly
The school year with its statutory work placed in the breaks: LEV tests ahead of their drifting due dates, lifts at summer and Christmas, the scheme and records around them.

Two refinements fit the sector. Book holiday examination slots a full term ahead, because every school in the county has the same thirteen weeks and the examiners' diaries fill in order of foresight. And run the September readiness check as a standing item: before the first practical lesson, the science and DT leads confirm every cupboard, hood, autoclave and machine is in test, in date and in service, so the worked example's discovery happens in August with weeks in hand, not in week one with a curriculum to reshuffle.

The standing audit is the sector's version of the two column check: per asset, maintained by whom and examined by whom, reconciled each summer, because school equipment contracts accumulate like textbooks and the examination is the column that goes missing.

Key point

Book the breaks a term ahead, let the 14 month clock drift on purpose, and run the September readiness check before the first practical: a school that uses its thirteen empty weeks never has to choose between compliance and curriculum.

Part 7 of 8

Documents and audiences: governors, insurers and the parent's question

A school's statutory file answers upward and outward at once. HSE reads it as the employer's LOLER, PUWER, PSSR and COSHH evidence, and education prosecutions cluster around exactly the equipment in this guide. The insurer's engineering schedule names the lifts, the autoclave and the pressure plant explicitly. Governors and trustees read it, or should, as the well run school's equivalent of the audited accounts: a compliance dashboard with every statutory date green. And behind all of them stands the parent's question after any incident, was the equipment checked, which the file answers in a minute or does not answer at all.

The filing standard mirrors every estate in this series: each fume cupboard and hood with its current test report and its commissioning benchmarks, the certified Written Scheme with its examination reports, the lifts' Reports of Thorough Examination, the machinery records, and the defect log with closure dates. Held centrally, indexed by asset, alongside the fire and water safety files the school already keeps, so the whole safety estate reads as one system.

The governance note worth making explicit: trusts running multiple schools should hold this at trust level, one dashboard across sites, because the worked example's dormant inbox is a school scale problem that multiplies by the academy.

Key point

The file that satisfies HSE satisfies the insurer, the governors and the parent's question in the same minute: hold it centrally, dashboard it at trust level, and treat every statutory date like the audited accounts.

Part 8 of 8

Running the programme: one body, holiday visits, a dashboard the trust can read

For a school or trust the efficient arrangement is one independent inspection body covering the LEV testing across science and DT, the autoclave and pressure plant schemes, and the lifts, in coordinated holiday visits, with the machinery record scope agreed alongside: one calendar, one report format, one invoice cycle, and reminders that arrive at the institution rather than a person. For a multi academy trust the same arrangement scales to a portfolio: one body across sites, defect gradings tracked centrally, and the estates team seeing every school's position on one page.

Independence carries its usual weight, the examiner outside every maintenance contract, and one sector specific advantage: an independent report reads cleanly to the widest audience list in this series, from HSE to a governor with no engineering background, because it certifies judgement rather than justifying a service relationship.

Close the loop on the school's rhythm: reports read within the week they land, failed cupboards and hoods out of service until fixed and retested, defect dates honoured inside the same half term, and the September readiness check confirming the whole estate before the first Bunsen lights. Run that way, the statutory estate becomes what it should be in a school: invisible to the children it protects, and one green line on the governors' dashboard.

Key point

One independent body, holiday visits booked a term ahead, a trust level dashboard and a September readiness gate: education compliance run on the calendar the sector is uniquely given.

Related services
Common questions

Schools, Colleges & Universities inspection FAQs

Do you work with schools and trusts like ours?

Yes. We inspect for individual schools, multi-academy trusts, sixth form and FE colleges and universities, from one passenger lift to a full multi-site estate programme.

How quickly can you attend?

Usually within a few working days, and we plan recurring work into holidays. Call 0330 043 8191 and we will build the calendar around your term dates.

How often do fume cupboards need testing?

At least every 14 months under COSHH Regulation 9, examined and tested by a competent person and benchmarked to HSG258, with CLEAPSS G9 the education reference. Reports are kept for five years. Our COSHH guide explains what the test covers.

Is a small prep room autoclave really a pressure system?

Yes. Steam is a relevant fluid at any pressure, so there is no small-vessel exemption: a certified Written Scheme of Examination before use, then examination to that scheme with the report within 28 days.

Are your engineers DBS checked?

Yes, every engineer surveyor attending an education site holds an enhanced DBS check, and we work to your safeguarding sign-in procedures as a matter of course.

What does the passenger lift need?

A thorough examination at least every 6 months because it carries people, alongside the maintenance contract, which does not replace the statutory examination. HSE guidance on the duty is at hse.gov.uk.

Does DT machinery need certificates?

No. Lathes, saws and sanders are PUWER work equipment inspected at risk-based intervals with a written record kept; there is no such thing as a PUWER certificate. The extraction serving them is the fixed-cycle item.

Can everything go into the summer holidays?

Mostly, yes. We front-load holidays with the disruptive work and keep only the interval-bound items in term time where the cycle demands it, planned so nothing statutory drifts past its date.

Book statutory inspections for your Schools, Colleges & Universities operation